ProfessionalHow toHow to handle sperm units

    How to handle sperm units

    Cryos provides donor sperm to over 100 countries and will work with you and your clinic to ensure quality of all specimens. Here we will discuss the handling of donor shipments and best practices for use.   


      Once you have ordered sperm units for your patients, and the shipment arrives at your clinic or facility, it is your responsibility to ensure that the sperm quality is maintained up until your patient’s fertility treatment. At Cryos we are here to assist you on this, and we recommend that you take a moment to read through this guide on how to handle sperm units after placing your order with Cryos. In that way, you will be prepared when the order arrives.  

      To ensure that your patients are treated with a high-quality product, it is important that you accurately follow the procedure as described below. 

        

      Handling Cryos donor sperm

      When you first receive the shipment please check the receipt to ensure the content within is undamaged. If transferring the frozen sperm units to another storage facility, it is important that the sperm units are moved quickly (within seconds) in order to avoid thawing.

      Identification of sperm sperm units

      • Donor sperm: The first number labeled on the sperm unit is the donor number, the second number labeled is the ejaculate number. (e.g. 4011-45, John-15).
      • For sperm units containing the customer's own sperm: The units are marked with a unique number, name or combination of both. The last number refers to the ejaculate number.

      Emptying the unit without an adapter

      To empty the sperm unit without an adapter, first clean the unit using an alcohol pad. Cut the sealing in both ends of the unit and empty the content into a test tube or similar container.

      Emptying the unit into a syringe with an adapter

      To empty the sperm unit with an adapter, please follow the step-by-step instructions listed below.

      Thaw the unit at room temperature between 22c-24c/72F-75F for approximately 15-20 minutes. If you want to perform a microscopic sperm analysis, it must be carried out just after thawing and before any preparation/use of sperm.

      Step 1: Clean the unit with an alcohol pad.

      Step 2: Cut the sealing in the opposite end of the label.

      Step 3: Fit the thick end of the adapter to the syringe.

      Step 4: Place the cut end of the unit into the thin end of the adapter. 

      Step 5: Check your unit type on the packing list.

      Determine the cut location by visually identifying the space between the end of the label and the cotton plug. If the space is clearly visible, cut at the specified location. If the space is not visible or cannot be accurately identified, measure the required distance from the reference point and make the cut according to the measurement.

      • CBS 0.5 ml units: Cut off the other end of the unit 2.5 cm/1” from the top of the unit by the ID-number.
      • CBS 0.4 ml and IMV units: Cut off the other end of the unit just below the plug under the ID-number.

      Step 6: Keep the syringe upright. Slowly draw the content out of the unit into the syringe.

      Step 7: Remove the adapter and unit from the syringe once the unit contents have been drawn into the syringe.

      At this point, the syringe and donor sample is ready for use.

      Handling of Cryos sperm units - step-by-step video 

      You can also watch this video about how to handle the sperm units:

      Do you have questions?

      If you need any further help or information about this process, please contact our Clinic Account Team via phone +1 (407) 203-1175 or our online chat for assistance.  